Search results will appear here

Weldex-DI (Double Insulated)

  • REACH
  • RoHS
  • CE
Weldex-DI (Double Insulated)
Weldex-DI (Double Insulated) Cross

Applications

Double insulated cable, for welding machines provides higher current carrying capacity. Used to conduct secondary voltage in secondary side connection to MMA welding power sources.

Technical Data

Voltage Rating: 450V a.c.r.m.s.

Test Voltage: 3000V

Temperature Range: -30°C to + 70°C

Minimum Bending Radius: 5 x cable diameter

Cable Construction

Super fine strands of annealed bare copper as per EN 60228, Cl. 6

Elastomeric PVC composite covering.

* Also available with TPE composite covering 105°C

Properties

The heavy duty welding cable is resistant to flame, oil, abrasions, tar and grease.

Suitable for use in open air, in dry as well as damp interiors.

The high degree of flexibility does not form knots on the cable which could lead to internal break of conductors.

Cable Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘y’) for the insulation material required:
0 – TPE, 1 – Elastomeric PVC

Part NumberNominal CrossSectional Area
(Sq. mm)
Max. Strand
Diameter (mm)
Max. DC Conductor
Resistance (Ω/km )
Total Radial
Thickness of
Covering (mm)
Maximum Cable
Diameter (mm)
Approx. Weight
(kg/km)
1207y0100010100.301.913.210.0180
1207y0100016160.301.213.211.5250
1207y0100025250.300.783.213.0350
1207y0100035350.300.5543.214.5460
1207y0100050500.300.3863.517.0650
1207y0100070700.300.2723.819.0880
1207y0100095950.300.2064.221.51170
1207y01001201200.300.1614.524.01430
1207y01001501500.300.1294.826.01720