Search results will appear here

PVC Insulated Building Wire (H07V-R) -6491x

  • REACH
  • RoHS
  • CE
  • CPR Compliant
PVC Insulated Building Wire (H07V-R) -6491x
PVC Insulated Building Wire (H07V-R) -6491x cross

Application

The cables are suitable for power and lighting circuits and building wiring suitable for use in semi flush exposed conduits, embedded conduits and in closed installation ducts.

Standard

BS EN 50525-2-31. SABS 1507-2, SS 358 Part-3.

Technical Data

Voltage Rating: Uo / U – 450 / 750V

Harmonised Designation: 1.5 mm² to 630 mm² stranded class 2 – H07V-R

Temperature Range: -15°C to 70°C

Minimum Bending Radius:

Upto 10 mm²: 3 X Overall Diameter.

16 & 25 mm²: 4 X Overall Diameter.

Above 25 mm²: 5 X Overall Diameter

Cable Construction

Conductor : Plain annealed copper conductor 1.5 mm² to 630 mm² stranded class 2 complying with BS EN 60228, HD 383, IEC 60228

Insulation : PVC (Polyvinyl Chloride ) compound type TI 1 complying with EN 50363-3, HD 21.1, IEC 60227-1, SABS 1411-2

Cabel Design Parameters

Kindly complete the part numbers for these cables by adding the suffix (in place of ‘xx’) for the colour required:
02 – black, 03 – red, 04 – blue, 05 – yellow, 06 – green / yellow, 07 – white, 08 – violet, 09 – brown, 10 – orange, 11 – pink, 12 – grey.

Part NumberNominal Cross
Sectional Area
(Sq. mm)
Nominal
Insulation
Thickness (mm)
Overall Diameter
Lower Limit
(mm)
Overall Diameter
Upper Limit
(mm)
Approx. Net
Weight (kg/km)
01140101xx101.50.702.703.3019
01140102xx102.50.803.304.0033
01140103xx1040.803.804.6050
01140104xx1060.804.305.2074
01140105xx10101.005.606.70126
01140106xx10161.006.407.80184
01140107xx10251.208.109.70295
01140108xx10351.209.0010.90375
01140109xx10501.4010.6012.80510
01140110xx10701.4012.1014.60710
Part NumberNominal Cross
Sectional Area
(Sq. mm)
Nominal
Insulation
Thickness (mm)
Overall Diameter
Lower Limit
(mm)
Overall Diameter
Upper Limit
(mm)
Approx. Net
Weight (kg/km)
01140111xx10951.6014.1017.10950
01140112xx101201.6015.6018.801240
01140113xx101501.8017.3020.901530
01140114xx101852.0019.3023.301800
01140115xx102402.2022.0026.602500
01140116xx103002.4024.5029.602990
01140117xx104002.6027.5033.203860
01140118xx105002.8030.5036.904900
01140119xx106302.8034.0041.106370
  • For current ratings refer table no. 10-1 & voltage drop refer table no. 10-2.

*Construction Product Regulation (CPR) is a regulation issued by the European Union with the purpose of regulating the limits of fire resistance and dangerous substances in the materials used in construction. This regulation applies to all products intended to be incorporated, permanently, in construction. Above link provides the DOP (declaration of performance) for the CPR compliance for the product.)